[ Identification | Description | Examples | Input parameters | Links ]

The Tomography Instrument

Instrument to study tomographic imaging by means of the feature of OFF shape samples.

Identification

Description

Instrument to study tomographic imaging by means of the feature of OFF shape samples.
The sample (geometry, an OFF file, default socket.off) is rotated by omega around the
vertical axis, and the transmitted beam is recorded on a 2D detector (monitor).

A tomography is a scan of omega over a full rotation. Settings suitable for a
full 3D reconstruction (72 projections of 4e6 rays each):
mcrun Tomography.instr omega=0:5:355 -n4e6 sigma_abs=1 -d TomoScan

Use the provided tomo_recon.py (numpy, scipy, matplotlib, pyqtgraph, h5py) in this folder to reconstruct a 3D
volume of the object from the scan directory: python tomo_recon.py TomoScan [--save]
(3 central slices + 3D isosurface; --save writes vol.nxs NeXus volume and surface.png;
--sirt 100 --median 3 gives fewer streaks than the default Hann FBP, see -h)

Examples

(Test cases in bold)

Input parameters

Parameters in boldface are required; the others are optional.
NameUnitDescriptionDefault
geometrystringName of the OFF file describing the sample shape"socket.off"
omegadegSample rotation around y0
sigma_absbarnSample absorption xs1
frac_scatt1Fraction of neutrons to scatter in the sample0
div_vdegSource vertical divergence (angular height)1e-4
div_hdegSource horisontal divergence (angular width)1e-4
source_wmSource width0.4
source_hmSource height0.2
det_wmDetector width0.25
det_hmDetector height0.15
optsstringMonitor_nD options string"x bins=128 y bins=64"